Appendix IRelationship between System Program and Hardware
276
Combining a -V1 Version and -V2 Version
Hardware
NT31-ST121j-EV1
NT31C-ST141j-EV1
NT31-ST121j-EV2
NT31C-ST141j-EV2
System program Ver. 2.0j or Ver. 2.1j
The following functions (new functions supported by the -V2) cannot be used:
S Additional data areas accessible in CS1-series PCs
S The CS1-series high-speed 1:N NT Link
S Interlock function that controls touch switches, numeral inputs, and character string inputs
S Mathematical function
S Device Monitor function
S NT30/620 compatible mode
S Expanded capabilities for label (guide character) displays, including multiple lines of text, ON/OFF switching
displays, numeral memory table displays, and character string memory table displays
System program Ver. 3.0j
All of the functions described in the Setup Manual and Reference Manual can be used.
* The system program’s version can be checked from the System Menu.
Combining a -V2 Version and Version without a -Vj Suffix
Hardware
NT31-ST121j-E
NT31C-ST141j-E
NT31-ST121j-EV2
NT31C-ST141j-EV2
System program Ver. 1.0j
The following functions cannot be used
S Analogue meter
S High-definition font display
S Installation of system programs using memory unit
S Connection to Mitsubishi PLCs
S Memory link
S Window control from the host
S Multiple display of window screens
S Moving a window
S Additional data areas accessible in CS1-series PCs
S The CS1-series high-speed 1:N NT Link
S Interlock function that controls touch switches,
numeral inputs, and character string inputs
S Mathematical function
S Device Monitor function
S NT30/620 compatible mode
S Expanded capabilities for label (guide character)
displays, including multiple lines of text, ON/OFF
switching displays, numeral memory table displays,
and character string memory table displays
The following functions cannot be used
S Analogue meter
S High-definition font display
S Connection to Mitsubishi PLCs
S Memory link
S Window control from the host
S Multiple display of window screens
S Moving a window
S Additional data areas accessible in CS1-series PCs
S The CS1-series high-speed 1:N NT Link
S Interlock function that controls touch switches,
numeral inputs, and character string inputs
S Mathematical function
S Device Monitor function
S NT30/620 compatible mode
S Expanded capabilities for label (guide character)
displays, including multiple lines of text, ON/OFF
switching displays, numeral memory table displays,
and character string memory table displays
* Installation of system programs using memory unit
is possible
System program Ver. 3.0j
The following functions cannot be used
S Installation of system programs using memory unit
S High-definition font display
All of the functions described in the Setup Manual and
Reference Manual can be used.
* The system program’s version can be checked from the System Menu.