Omron NT31 NT31C Network Card User Manual


 
3-2SectionConnecting to the Support Tool
35
3-2 Connecting to the Support Tool
In order to install the system program in the NT31/NT31C, or to transmit screen
data created with the Support Tool to the NT31/NT31C, the NT31/NT31C must
be connected to a personal computer with an RS-232C cable.
The NT31/NT31C connects the RS-232C cable from a personal computer at se-
rial port A. When the host is connected at serial port B, the connection with the
host can be maintained as it is while the NT31/NT31C is connected to the
RS-232C cable from a personal computer.
However, when a bar code reader is being used, it must be disconnected, so that
the RS-232C cable can be connected, since they both use serial port A.
PRINTER PORT B PORT A
Serial port A
(RS-232C, 9-pin)
Communication Conditions
The communication conditions are automatically set when the system installer
and Support Tool are started.
Recommended Connector Cable
Use the cable indicated below.
CV500-CN228 (length: 2 m), made by OMRON
(D-SUB 9-pin, male D-SUB 25-pin, male)
XW2Z-S001 (conversion cable), made by OMRON
(D-SUB 25-pin, female half pitch 14-pin, male)
XW2Z-S002 (length: 2 m), made by OMRON
(D-SUB 9-pin, male D-SUB 9-pin, female)
For details on making a connector cable, refer to Appendix F Making the Cable
for Connecting a PC (page 269).