3-5SectionUsing a Memory Unit (-Vj Versions)
45
(The second line may not be displayed in the kind of system program.)
Current PT Screen Data, Screen
The comment for the screen data in the NT31/NT31C is displayed here.
Current Memory Unit Screen Data
In the case of system program:
The first line: Compatible PT type for the system program inside the
memory unit.
The second line: System program name and Version for the system pro-
gram inside the memory unit.
(The second line may not be displayed in the system program for some
models.)
In the case of screen data:
The comment for the screen data in the NT31/NT31C is displayed here.
The available transmitting destinations are altered depending on the settings of
the origin of transmitting as described in the table below.
Source Destination
[PT]screen
[Memory unit] Bank 0
[Memory unit] Bank 1
[PT]system
[y]
[y]
[PT]system/screen [Memory unit] Bank 0/1 (fixed)
[Memory unit] Bank 0
S If system program is selected
[PT]system (fixed)
[Memory unit] Bank 1
y()
S If screen data is selected
[PT]screen (fixed)
[Memory unit] Bank 0/1 [PT]system/screen (fixed)
Reference: S When transmitting the system program and screen data simultaneously from
the PT to the memory unit, the setting of banks is Bank 0: system program,
Bank 1: screen data, and when transmitting them from the memory unit to the
PT, either of the following combinations must be used.
Bank 0: system program, Bank 1: other than system program
Bank 0: other than system program, Bank 1: system program
S When writing the system program into the NT31/NT31C, the type of system
program inside memory unit and the type of PT unit must be corresponding.
4. Press Execute.
The data is transmitted.
The messages Preparing, Transmitting, Verifying, and Finished are dis-
played in accordance with the progress of data transmission. At the same
time, the progress of data transmitting status is displayed by the means of
the number of bytes and blocks (1 bank = 16 block = 1024k byte).
When the data transmission is operated manually, RUN LED remains OFF.
5. Switch the NT31/NT31C power OFF, remove the memory unit, then switch
the NT31/NT31C power back ON.
If an error occurs when using the memory unit, the NT31/NT31C operates as
follows.
The details of the error and remedial action are displayed on the screen.
Each screen has touch switches to change the display language from one to
the other. When the manual data transmission is operating, the content of
error and remedial action are shown with selected language. When the au-
tomatic transmission is operating, it is displayed in Japanese.
Errors When Using a