Omron NT31 NT31C Network Card User Manual


 
2-1SectionMethod for Connection to the Host
26
2-1 Method for Connection to the Host
This section describes the methods for connection to the host used with the
NT31/NT31C, and the relationship between the connection method and the
communication method.
NT31/NT31C Communication Ports and Communication Methods
The NT31/NT31C has two communication ports. Their uses are indicated in the
table below.
Communication
Port
Usable Communication Methods Communication Type
Serial port A
Host link
NT link (1:1)
NT link (1:N)
*
Memory link
(Support Tool connection)
(bar code reader input function)
RS-232C
Serial port B
Host link
NT link (1:1)
NT link (1:N)
*
Memory link
RS-232C
RS-422A/485
(select between RS-232C
and RS-422A/485)
* There are two NT Link (1:N) communications rates: standard and high-speed.
Communication Methods That Can Be Used with the Host
The following communication methods can be used with the hosts that can be
connected to the NT31/NT31C.
RS-232C
RS-422A
RS-485
The communication types that are actually supported differ depending on the
host unit. For details, refer to Section 4 Connecting to the Host from the
RS-232C Port and Section 5 Connecting to the Host from the RS-422A/485 Port.
Converting the Communication Type with an RS-232C/RS-422A Convertor
Unit
The following communication type conversions are possible by using an
RS-232C/RS-422A convertor unit (NT-AL001-E, made by OMRON).
RS-232C RS-422A
RS-232C RS-485