Optiquest iRIS 220 Switch User Manual


 
iRIS 220 / iRIS 320, V1.19 User Guide - 48
48
iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857-0810 Fax: +64 7 857-0811 Email: iquest@iquest.co.nz
Total 2 Screen 2/2 (Level 3)
Reset Total Screen (Level 4)
The Total Reset screen is used to reset the daily and running totals.
NOTE: The two pulse counters' totalisers operate continually, irrespective of whether or not they are
configured as a source for any of the sensors.
5.2.8 Comms Related Screens
Comms Status Screen (Level 3)
The Comms Status screen displays the current state of the GPRS/CDMA-1X or CSD connection. The RSSI
display shows the Received Signal Strength Indication (RSSI) followed by the Bit Error Rate (BER). The iRIS
320 will not attempt to connect if the RSSI value is less than 6.
Comms Menu Screen (Level 4)
The comms menu screen is used to select communication options.
Comms Setting Screen 1/8 - Protocol (Level 5)
The GPRS/CDMA-1X Protocol screen displays the station address and type of base that the unit must
communicate with.
COMMS STATUS
On Line
Connected
RSSI: 23,00
COMMS MENU
>Settings
Enable
Test
GPRS/CDMA 1/8
PROTOCOL
Addr 123
Auto Send
TOTAL 2/2
Yst 76.5
Day 26.4
Run 11276.3
RESET TOTAL
initiate
+/- Move forwards/backwards through sensor total screens
Enter Drill down to Total Reset screen
Alt Enter Move up to Main Menu screen
Enter Reset total and move up to Sensor Total screen
Alt Enter Move up to Sensor Total screen
Enter Move down to Comms Menu screen
Alt Enter Move up to Main Menu screen
+/- Move down/up through menu
Enter Select menu item
Alt Enter Move up to Comms Status screen
+/- Move forwards/backwards through communication setting screens.
Alt Enter Move up to Comms Status screen