86 Chapter 5 Configuring RMON using the CLI
Figure 32
show rmon stats command output
rmon alarm
The rmon alarm command allows you to set RMON alarms and
thresholds. The syntax for the rmon alarm command is:
rmon alarm <1-65535> <WORD> <1-2147483647> {absolute | delta}
rising threshold <-2147483648-2147483647> [<1-65535>]
falling-threshold <-2147483648-2147483647> [<1-65535>]
[owner <LINE>]
The rmon alarm command is in the config command mode.
Table 33 "rmon alarm command parameters and variables" (page 86)
describes the parameters and variables for the rmon alarm command.
Table 33
rmon alarm command parameters and variables
Parameters and variables Description
<1-65535>
Unique index for the alarm entry.
<WORD>
The MIB object to be monitored. This
is an object identifier (OID) and, for
most available objects, an English
name can be used.
Nortel Ethernet Switch 460/470
Configuration — System Monitoring
NN47210-503 01.01 Standard
3.7 22 February 2007
Copyright © 2005-2007, Nortel Networks Nortel Networks Confidential
.