94 Chapter 6 Configuring RMON using Device Manager
Field Description
Interval The interval in seconds over which the data is sampled
for each bucket in the part of the media-specific table
associated with this entry. You can set this interval to
any number of seconds between 1 and 3600 (1 hour).
Because the counters in a bucket can overflow at their
maximum value with no indication, note the possibility
of overflow in any of the associated counters. It is
important to consider the minimum time in which any
counter can overflow on a particular media type; set the
historyControlInterval object to a value less than this
interval. This is typically most important for the octets
counter in any media-specific table. For example, on
an Ethernet network, the etherHistoryOctets counter
can overflow in about one hour at the Ethernet
maximum utilization.
Owner The network management system that created this
entry.
Disabling history
To disable RMON history on a port:
Step Action
1
From the Device Manager main menu, choose Rmon > Control.
The RmonControl dialog box opens with the History tab displayed
(Figure 33 "History tab" (page 92)).
2
Highlight the row that contains the port ID you want to delete.
3 Click Delete.
The entry is removed from the table.
—End—
Viewing RMON history statistics
To display RMON history statistics:
è In the Rmon History tab, highlight an entry and click on the Graph button.
The Rmon History statistics dialog box opens (Figure 35 "Rmon History
statistics" (page 95)).