Panasonic 470 Switch User Manual


 
no rmon alarm 87
Parameters and variables Description
<1-2147483647>
The sampling interval in seconds.
absolute
Use absolute values (value of the
MIB object is compared directly with
thresholds).
delta
Use delta values (change in value of
the MIB object between samples is
compared with thresholds).
rising-threshold
<-2147483648-2147483647>
[<1-65535>]
The first integer value is the rising
threshold value. The optional second
integer specifies the event entry
triggered when the rising threshold
is crossed. If omitted, or if an invalid
event entry is referenced, no event is
triggered.
falling-threshold
<-2147483648-2147483647>
[<1-65535>]
The first integer value is the falling
threshold value. The optional second
integer specifies the event entry
triggered when the falling threshold
is crossed. If omitted, or if an invalid
event entry is referenced, no event is
triggered.
[owner <LINE>]
Specifies an owner string to identify
alarm entry.
no rmon alarm
The no rmon alarm command deletes RMON alarm table entries. When
the variable is omitted, all entries in the table are cleared. The syntax for
the no rmon alarm command is:
no rmon alarm [<1-65535>]
The no rmon alarm command is in the config command mode.
Table 34 "no rmon alarm command parameters and variables" (page 87)
describes the parameters and variables for the no rmon alarm command.
Table 34
no rmon alarm command parameters and variables
Parameters and variables Description
<1-65535>
Unique index for the alarm entry.
Nortel Ethernet Switch 460/470
Configuration System Monitoring
NN47210-503 01.01 Standard
3.7 22 February 2007
Copyright © 2005-2007, Nortel Networks Nortel Networks Confidential
.