Premier Mounts CDM-600 Modem User Manual


 
16–1
Chapter 16. REMOTE CONTROL
16.1 Introduction
This section describes the protocol and message command set for remote monitor and
control of the CDM-600 Modem.
The electrical interface is either an EIA-485 multi-drop bus (for the control of many
devices) or an EIA-232 connection (for the control of a single device), and data is
transmitted in asynchronous serial form, using ASCII characters. Control and status
information is transmitted in packets, of variable length, in accordance with the structure
and protocol defined in later sections.
16.2 EIA-485
For applications where multiple devices are to be monitored and controlled, a full-duplex
(or 4-wire) EIA-485 is preferred. Half-duplex (2-wire) EIA-485 is possible, but is not
preferred.
In full-duplex EIA-485 communication there are two separate, isolated, independent,
differential-mode twisted pairs, each handling serial data in different directions. It is
assumed that there is a ‘controller’ device (a PC or dumb terminal), which transmits data,
in a broadcast mode, via one of the pairs. Many ‘target’ devices are connected to this
pair, which all simultaneously receive data from the controller. The controller is the only
device with a line-driver connected to this pair - the target devices only have line-
receivers connected.
In the other direction, on the other pair, each target has a tri-stateable line driver
connected, and the controller has a line-receiver connected. All the line drivers are held in
high-impedance mode until one (and only one) target transmits back to the controller.