CDM-600 Satellite Modem Revision 7
Remote Control MN/CDM600.IOM
16–30
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Retrieve next
5 unread
Stored
Events
N/A 80 bytes Query only.
Unit returns the oldest 5 Stored Events which have not
yet been read over the remote control.
Reply format: [CR]sub-body[CR]sub-body[CR]sub-
body[CR]sub-body[CR]sub-body, where Sub-
body=ABCddmmyyhhmmss,
A is the fault/clear indicator:
F=Fault
C=Clear
I=Info
B is the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
5=Open Network
C is Fault Code number, as in FLT?
or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
ddmmyyhhmmss = date/time stamp.
If there are less than 5 events to be retrieved, the
remaining positions are padded with zeros.
If there are no new events, the response is RNE*.
N/A RNE? RNE=[CR]ABCddmm
yyhhmmss[CR]ABC
ddmmyyhhmmss[CR
]ABCddmmyyhhmm
ss[CR]ABCddmmyy
hhmmss[CR]ABCdd
mmyyhhmmss
(see description for
details of
arguments)
Clear All
Stored
Events
CAE= None Command only.
Forces the software to clear the software events log.
Example: CAE=
Note: This command takes no arguments
CAE=
CAE?
CAE*
CAE#
N/A N/A