CDM-600 Satellite Modem Revision 7
Front Panel Operation MN/CDM600.IOM
6–29
backward alarm inputs are to be used. An activated alarm may respond to a hardware
input at P5A (H/W) or be software controlled by a receive fault on the modem (S/W).
CONFIG: MASK: SATELLITE ALARMS: RX
Select which Receive IDR backward alarms are to be monitored.
CONFIG: MASK: TERR-ALM
These alarms are only valid for D&I operation.
Use the [←] [→] arrow keys to select the parameter to edit. Edit the alarms using the [↑]
[↓] arrow keys, then press ENTER.
6.3.1.11 CONFIG: IMPEDANCE
Select either 50 or 75Ω, using the [↑] [↓] arrow keys, then press ENTER.
Note that this affects both the Rx and Tx IF ports simultaneously.
6.3.1.12 CONFIG: STATISTICS
Edit the logging interval (the period of time over which the statistics will be measured),
using the [↑] [↓] arrow keys, then press ENTER. Setting a value of 00 disables the
feature (no logging).
The user can choose 00, 10, 20, 30, 40, 50, 60, 70, 80, or 90 minutes. For more
information about the Statistics data taken, refer to Section 6.3.4.3 Monitor: Statistics.
PROCESS ALARMS RECEIVED FROM SATELLITE
BWA1=N, BWA2=N, BWA3=N, BWA4=N
TERR-ALM: TX = ACTIVE (ACTIVE,MASK)
RX = OFF (OFF,ENABLED)
IF IMPEDANCE = 50 (50,75 OHMS)
LINK STATISTICS LOGGING INTERVAL:
00 minutes (00 TO 90)