Premier Mounts CDM-600 Modem User Manual


 
CDM-600 Satellite Modem Revision 7
Front Panel Operation MN/CDM600.IOM
6–26
If the Warm-up Delay is enabled, when the modem is powered up, a Warm-Up Delay
Countdown will be activated, during which the TX is suppressed. The Countdown of the
remaining Warm-up Delay is displayed on the front panel, for example:
If necessary, this Warm-up period can be by-passed by pressing the CLEAR key.
6.3.1.9 CONFIG: REMOTE CONTROL
Select LOCAL or REMOTE using the [] [] arrow keys, then press ENTER.
If LOCAL is selected, the REMOTE CONTROL is disabled. Remote monitoring is
still possible.
If REMOTE is selected, then the following sub-menus will be displayed.
ONFIG: REMOTE CONTROL: INTERFACE
Use the [] [] arrow keys to select the parameter to edit: Interface, Address or
Baudrate.
Edit the Interface type, Baudrate and each digit of the Address using the [] [] arrow
keys.
For EIA-485, the permitted address range is 1 to 9999.
Address 0 is reserved for universal addressing.
For EIA-232, the Address is fixed at 0000.
REMOTE CONTROL = LOCAL (LOCAL,REMOTE)
INTERFACE= RS-485-4W (232,485-2,485-4)
ADDRESS= 0001 BAUDRATE= 9600
COMTECH CDM-600 OPEN NETWORK MODEM
HIGH-STABILITY REF WARMING UP: 045 SEC