CDM-600 Satellite Modem Revision 7
Remote Control MN/CDM600.IOM
16–35
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and
Status
N/A 6 bytes
Query only.
Response is the current fault and status codes, in the form abcdef, where:
a = Unit faults:
0=No faults
1=Power supply fault, +5 volts
2=Power supply fault , +12 volts
3=Power supply fault, –5 volts
4=Power supply fault, +18 volts
5=Power supply fault, –12 volts
6=Spare
7=Tx synthesizer lock
8=Rx synthesizer
9=Power cal Checksum error
A=FPGA main chain load fail
B=Turbo FPGA load fail
C=Modem card FPGA load
D=MUX FPGA load
E=Demux FPGA load
F=(Hi-Stab module) No PLL Lock (Note: suppresses TX)
b = Tx Traffic status:
0=Tx traffic OK
1=No clock from terrestrial interface
2=Tx FIFO slip
3=AIS detected on incoming data
4=AUPC upper limit reached
5= (Hi-Stab module) Ref Activity fault
c = Rx Traffic status:
0=Rx Traffic OK
1=Demodulator unlocked
2=AGC Alarm - signal out of range
3=Demux Lock (Frame SYNC)
4=Spare
5=Buffer Slip
6=AIS detected on incoming data
7=Eb/No alarm
8=Buffer Clock activity
d = Open Network:
0=No Faults
1=Loss of Tx frame
2=BER Alarm
3=Loss of Tx multiframe
4=Tx signaling AIS
5=Tx Remote alarm
6=IBS satellite alarm
7=IDR Rx BWA1
8=IDR Rx BWA2
9=IDR Rx BWA3
A=IDR Rx BWA4
B=IDR Tx BWA1
C=IDR Tx BWA2
D=IDR Tx BWA3
E=IDR Tx BWA4
N/A FLT? FLT=abcdef
(see description for
details of arguments
e=Change in fault
status since last poll.
f=Change in unit
configuration since
last poll.