PSC 8500 Barcode Reader User Manual


 
3URGXFW5HIHUHQFH*XLGH 6-121
83&$6XSSOHPHQWDO/DEHO,'
This feature specifies a UPC-A 128 Supplemental label ID to be added to
bar code data.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET UPC-A 128 SUPPLEMENTAL LABEL
ID below. You’ll need to cover any unused bar codes on this and
the facing page to ensure the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired Label ID characters; entered as two hex
pairs. A table containing the ASCII Character Set and their corre-
sponding Hex Values is available in the inside back cover of this
manual. ASCII parameters must be input by scanning a pair of
hexadecimal digits for each character. Thus, to set a two-character
value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’
must be scanned. The selectable range for this option is any hex
value from 00 to FF.
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET UPC-A 128 SUPPLEMENTAL LABEL ID
NOTE
The programming feature, RS-232 Label ID Control, designates
whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis-
abled.