PSC 8500 Barcode Reader User Manual


 
6-236 0DJHOODQ 6FDQQHU
&RGDEDU0LQLPXP/DEHO/HQJWK
This feature specifies the minimum allowable length of a Codabar label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET CODABAR MINIMUM LABEL
LENGTH below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired minimum label length. The selectable range
for this option is 03 to 50. Pad all single digit numbers with a
leading zero to yield a two-digit entry (03-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODABAR MINIMUM LABEL LENGTH
NOTE
Length in this case includes start, stop or check and data characters, but
does not include full ASCII shift characters. This feature applies when
Codabar Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label
length.