3URGXFW5HIHUHQFH*XLGH 6-265
6WDQGDUGRI/DEHO,'
This feature specifies an Standard 2 of 5 label ID to be added to bar code
data.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET STANDARD 2 of 5 LABEL ID below. You’ll
need to cover any unused bar codes on this and the facing page to
ensure the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that rep-
resent the desired Label ID characters; entered as two hex pairs. A
table containing the
ASCII Character Set and their corresponding
Hex Values is available in the inside back cover of this manual.
ASCII parameters must be input by scanning a pair of hexadecimal
digits for each character. Thus, to set a two-character value of AB,
bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned.
The selectable range for this option is any hex value from 00 to FF.
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET STANDARD 2 of 5 LABEL ID
NOTE
The programming feature, RS-232 Label ID Control, designates
whether the Label ID is transmitted as a prefix or suffix or if Label ID is
disabled.