6-124 0DJHOODQ 6FDQQHU
83&(&KHFN&KDUDFWHU7UDQVPLVVLRQ
Enables/disables transmission of a UPC-E check character.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to
cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
UPC-E CHECK CHARACTER TRANSMISSION = DISABLE
UPC-E CHECK CHARACTER TRANSMISSION = ENABLE
NOTE
This item is ignored when the advanced feature, Full Label Edit, is enabled.