6-220 0DJHOODQ 6FDQQHU
,RI0D[LPXP/DEHO/HQJWK
This feature specifies the maximum allowable length of an I 2 of 5 label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET I 2 OF 5 MAXIMUM LABEL LENGTH
below. You’ll need to cover any unused bar codes on this and the
facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired maximum label length. The selectable range
for this option is 02 to 50, even numbers only. Pad all single digit
numbers with a leading zero to yield a two-digit entry (02-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET I 2 OF 5 MAXIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters, but does not
include start or stop characters. This feature applies when I 2 of 5
Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label