PSC 8500 Barcode Reader User Manual


 
3URGXFW5HIHUHQFH*XLGH 6-179
566([SDQGHG0D[LPXP/DEHO/HQJWK
This feature specifies the maximum allowable length of an RSS Expanded
label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET RSS EXPANDED MAXIMUM LABEL
LENGTH below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired maximum label length. The selectable range
for this option is 00 to 74. Pad all single digit numbers with a
leading zero to yield a two-digit entry (00-74).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET RSS EXPANDED MAXIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters. This applies
when RSS Expanded Length Control is set to variable-length
decoding.
Maximum Label Length should be greater than or equal to Minimum Label
Length.