3URGXFW5HIHUHQFH*XLGH F-1
$SSHQGL[ )
+DQGKHOG'DWD)RUPDW5HTXLUHPHQWV
This appendix provides application notes to describe the general format of
data that can be accepted by the scanner through the auxiliary port as
transmitted from a handheld scanner.
+DQGKHOG'DWD)RUPDW5HTXLUHPHQWV*HQHUDO
• 9600 bps, 8 data bits, 1 stop bit, no parity.
• RTS is used to "bracket" the data received from the handheld:
RTS must be asserted high during data transmission, and de-
asserted after label transmission is complete. No other flow con-
trol mechanisms are required or supported.
• Symbologies requiring fixed lengths (UPC/EAN) will enforce
length requirements for validation of the label.
• Handheld will be required to transmit start and stop characters
for Codabar and Code 39 labels.
• Appropriate industrial length requirements will be enforced (if
configured) for validation of the label.
• Maximum label lengths will be enforced for label validation (i.e.
labels longer than the maximum label size will not be validated).
• Standard PSC formats generally use a single prefix character. The
specific formats are provided below.