Samsung SMG-3200 Network Card User Manual


 
5-35
3. Set the CO tone cadence referring to the following table, and press [Enter].
Typed number x 50msec is the actual time.
No
NoNo
No Item
ItemItem
Item Item in Detail
Item in DetailItem in Detail
Item in Detail Description
DescriptionDescription
Description
BUSY CO TONE
1
st
on Time
The time elapsed for the first busy tone
to be On.
BUSY CO TONE
1
st
off Time
The time elapsed for the first busy tone
to be Off.
BUSY CO TONE
2
nd
on Time
The time elapsed for the second busy
tone to be On.
0
Busy
(Trunk
Busy
Tone)
BUSY CO TONE
2
nd
off Time
The time elapsed for the second busy
tone to be Off.
RING BACK CO
TONE 1
st
on Time
The time elapsed for the first ring back
tone to be On.
RING BACK
CO TONE 1
st
off
Time
The time elapsed for the first ring back
tone to be Off
RING BACK
CO TONE 2
nd
on
Time
The time elapsed for the second ring
back tone to be On
1
Ring
Back
(Trunk
Ring
Back
Tone)
RING BACK
CO TONE 2
nd
off
Time
The time elapsed for the second ring
back tone to be Off.
DIAL CO TONE
1
st
on Time
The time elapsed for the first dial tone to
be On.
DIAL CO TONE
1
st
off Time
The time elapsed for the first dial tone to
be Off.
DIAL CO TONE
2
nd
on Time
The time elapsed for the second dial tone
to be On.
2
Dial
(Trunk
Dial
Tone)
DIAL CO TONE
2
nd
off Time
The time elapsed for the second dial tone
to be Off.