4-11
8. Configured network parameters and message asking you whether to restart system is displayed
as follows. After confirming the parameters type ‘y’ and press [Enter].
Good
>>> IP Address = 165.213.81.230
>>> Gateway = 165.213.81.1
>>> Subnet Mask = 255.255.255.0
>>> TOS = 0
# System Configuration has changed. Restart? (y: Now, n: Later) -> y
9. Log in again on CLI after the system is restarted.
Configuring the System Operation Mode
You have to configure gateway operation mode and PCM type, after TCP/IP configuration.
This section describes procedures for system operation configuration.
Setting up Gateway Operation Mode
SMG-3200 gateway operates in either of the following 2 operation modes.
Tandem Gateway : SMG-3200 communicates with PBX or KTS over PSTN trunk without
subscriber phone connection.
Standalone Gateway : SMG-3200 communicates with analog telephone with PSTN trunk
with subscriber phone connection through SLC port.
Configure gateway operation mode of SMG-3200 referring to the following directions.