Code 93
Command Structure 1:3 ratio: <ESC>BCbbcccdd (data)
bb = Width of narrow element in dots (01-12)
ccc = Bar height in dots (001-600)
dd = Length of data (number of digits, 00-99)
(data) = Bar code data (alphanumeric); length must match value of
parameter “dd”; check digit is supplied by printer
Character Set 0-9, A-Z, -, ., Space, $, /, +, %
Density Table
Narrow/Wide
Ratio
Value of
“bb”
“X”
Dimension
(mils)
Density
(char/inch)
1:3 01 5.0 22.5
1:3 02 10.0 11.3
1:3 03 15.0 7.5
Example <ESC>H0100<ESC>V1125<ESC>BC03100081234ABCD
<ESC>H0155<ESC>V1240<ESC>XS1 234ABCD
Appendix B: Bar Code Specifications
PageB-129001041Rev.DSATOM-8400RV