SATO CL412E Printer User Manual


 
83-84 Hex Assent in dots
85-86 Hex Registration Start Code
86-87 Hex Registration End Code
88-95 Hex Reserved
96-98 Hex Code
99-100 Hex Horizontal Valid Size
101-102 Hex Left Gap Size
Interface Status
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII IG
causes the printer to return a 1 byte Interface Status Word bounded by an STX-ETX
pair that reports the type of interface connection currently set in the printer.
BYTE
NUMBER
VALUE DESCRIPTION
10
1
2
3
IEEE 1284 Parallel
Serial RS232
Local Area Network
Universal Serial Bus
Serial Interface Settings
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII H2
causes the printer to return a 5 byte Serial IF Status Word bounded by an STX-ETX
pair that reports the current operating parameters of the Serial RS232 Interface.
BYTE
NUMBER
VALUE DESCRIPTION
10
1
2
3
9600 BPS
19200 BPS
38400 BPS
57600 BPS
20
1
3
No Parity
Odd Parity
Even Parity
30
1
1 Stop Bit
2 Stop Bits
40
1
2
3
4
Single Item Buffer with Ready/Busy Flow Control
Multi-Item Buffer with Ready/Busy Flow Control
X-ON/X-OFF Flow Control
Status 4 Bi-Comm
Status 3 Bi-Comm
SATO CL Series “e” Printers PN 9001074 Preliminary Page 6-17
Section 6. Interface Specifications