External Signal Type Selection (DSW3-6, DSW3-7). Both the polarity and
signal type (level or pulse) of the external print synchronizing signal can be selected.
See Section 6: Interface Specifications for a definition of signal types.
Repeat Print via External Signal (DSW3-8). Allows the applicator to reprint
the last label of the print job. See Section 6: Interface Specifications for a description of
the signal requirements.
SATO CL Series “e” Printers PN 9001074 Preliminary Page 3-5
Section 3. Configuration
DSW3-6 DSW3-7 SETTING
Off Off Type 4
Off On Type 3
On Off Type 2
On On Type 1
12345678
ON
OFF
DSW3
DSW3-8 SETTING
Off Disabled
On Enabled
12345678
ON
OFF
DSW3