Sun Microsystems CP3220 Server User Manual


 
2-10 Sun Netra CP3220 Blade Server User’s Guide January 2010
To Install an ARTM
1. Verify that you have taken the necessary antistatic precautions.
See Section 2.1.1, “Equipment and Operator Safety” on page 2-2.
2. From the rear of the system, choose an appropriate slot for the ARTM.
The ARTM must be installed, inline, behind a compatible Sun Netra blade server
(Sun Netra CP3220 blade server or Sun Netra CP3260 blade server).
For example, if the Sun Netra CP3220 blade server will be installed in slot 3, the
corresponding ARTM must be installed at the back of the system in slot 3
(
FIGURE 2-1). If you do not install the ARTM and the Sun Netra CP3220 blade
server in corresponding slots, the system will recognize the Sun Netra CP3220
blade server, but not the ARTM.
Note Slots 1 through 6 and 9 through 14 are available for Sun Netra CP3220 blade
servers. Slots 7 and 8 are reserved for the switch card.
3. Remove the slot filler panel from the selected slot, if necessary.
4. Retrieve the ARTM from the ship kit.
5. Prepare the ARTM by opening the injector/ejector latch at the top of the
module (
FIGURE 2-2).