2-22 Sun Netra CP3220 Blade Server User’s Guide • January 2010
FIGURE 2-5 Installing a DIMM
6. Press the top edge of the DIMM toward the blade server until the retainer clips
click into place in the notches on the DIMM sides (
FIGURE 2-5).
The small metal retainer clips on each side of the DIMM slot are spring-loaded,
and they should click into place in the notches on the sides of the DIMM.
2.3.6.3 Removing a DDR2 DIMM
If you are returning the DIMM or the blade server for service, or if you are replacing
a DIMM with another DIMM, remove the DIMM from the Sun Netra CP3220 blade
server.
Note – Safely store the original factory-shipped DIMM and related DIMM
packaging. Store any removed DIMM in the new DIMM packaging.
To remove a DIMM from the Sun Netra CP3220 blade server, perform the following
steps:
1. Access the blade server by performing one of the following procedures:
■ If the Sun Netra CP3220 blade server is installed in an ATCA shelf, remove the
blade server from the shelf as explained in Section 2.3.3, “Removing the Sun
Netra CP3220 Blade Server” on page 2-18.
■ Remove the Sun Netra CP3220 blade server from its antistatic envelope and place
it on an ESD mat near the ATCA shelf.