Sun Microsystems Sun Fire V100 Server User Manual


 
100 Sun Fire V100 Server User’s Guide December 2001
Diagnostic Tools
The following troubleshooting tools are available for the servers:
Power On Self Test (POST) Diagnostics
OpenBoot Diagnostics (OBDiag)
SunVTS
POST Diagnostics
To view Power On Self Test (POST) diagnostic and error messages you need to have
a serial connection set up to the server. For more information, see “Setting Up a
Console Connection to the Server” on page 20.
If the OpenBoot PROM (OBP) variable diag-switch? is set to true, then POST
diagnostics will run automatically when you power on the server. However, the
default setting for diag-switch? is false.
To initialize POST diagnostics, you need to set the diag-switch? variable to true
and diag-level to max or min, and then power cycle the server. From the ok
prompt:
1. Type:
2. Type:
The system will now run POST diagnostics and display status and error messages in
your console window. If POST detects an error, it displays an error message
describing the failure. A sample error message is shown below:
ok setenv diag-switch? true
ok reset-all
Power On Self Test Failed. Cause: DIMM U0702 or System Board