24 Sun Fire V100 User’s Guide • December 2001
■ RJ-45 to RJ-45 patch cable
Both are supplied with the Sun Fire V100 server.
▼ To Connect to the Server Using a Sun
Workstation
1. Connect to the server using the RJ-45 patch cable and DB-25 adapter as described
in “To Use the DB-25 Adapter” on page 23.
2. From a terminal session, type:
The tip command above is for a console that is using its ttya serial port. If you later
configure your console to use ttyb, type the following to set up a tip session:
For information about dedicating the console to Serial B, see “Managing the Sun Fire
V100 Server From the lom> Prompt” on page 43.
For information about how to power on and configure the server, go to “Powering
On and Configuring the Server” on page 34.
▼ To Connect to the Server Using an ASCII
Terminal
1. Set up a connection between the terminal and the Sun Fire V100 server.
See “To Use the DB-25 Adapter” on page 23.
2. For the General terminal settings, refer to the terminal operating manual.
# tip /dev/term/a -9600
# tip /dev/term/b -9600