122 Sun Fire V100 Server User’s Guide • December 2001
disable_wdog_on_break= Boolean
0=FALSE
1=TRUE
1 Causes LOM to disable its
watchdog if it detects a break
signal on the Serial A/LOM
port.
disable_wdog_on_panic= Boolean
0=FALSE
1=TRUE
1 Causes LOM to try to disable its
watchdog after a system
“panic”.
faulty_voltage_shutdown= Boolean
0=FALSE
1=TRUE
1 Causes LOM to attempt first to
shut down the system and, if
that fails, to power off the
system in the event of a
problem with the supply rails.
enclosure_warning_temp=
o
C 67 Specifies the temperature at
which LOM generates an
overtemperature event.
over_temperature_shutdown= Boolean
0=FALSE
1=TRUE
1 Causes LOM to attempt to shut
down the system, or to power it
off, if the enclosure temperature
exceeds the level specified for
the enclosure_shutdown_temp
parameter.
enclosure_shutdown_temp=
o
C 72 Specifies the enclosure
temperature above which LOM
attempts to shut the system
down or, if this fails, to power
the system off. (LOM will
attempt to do either of these if
over_temperature_shutdown is
set to 1.)
serial_security= Boolean
0=FALSE
1=TRUE
1 Enables and disables the user
security facilities even if user
security has been configured.
You can use this parameter to
set up users again if your users
have forgotten their passwords.
Cannot be turned on if no users
are configured in the LOM.
TABLE B-1 LOM Configuration File Parameters (Continued)
Field Format Default Effect