Appendix A Physical and Environmental Specifications 117
Environmental Compliance Information
Electromagnetic compatibility
Immunity: The server conforms to EN55024.
Emissions: The server conforms to EN55022 Class A and FCC Class A.
Safety
The system conforms to UL 1950 (3rd edition), EN60950
Operating Power Statistics
* The in-rush current decays to the normal operating current in less than 200 msecs.
Caution The power supply continues to regulate all outputs for at least 17 ms
after AC power is removed.
Note Logic ground and chassis ground are connected internally.
TABLE A-2 Operating Power Statistics
Maximum operating current 1.3A @ 100 VAC
Typical operating current See “Calculating Power Consumption” on
page 118
Maximum in-rush
current (cold start)*
40A peak at 115V
25˚C
Maximum in-rush
current (warm start, or upon a restart 20 to
200 msecs after power has been removed
*
)
100A peak at 115V
25˚C
Operating input voltage range 90 to 264 Vrms
Voltage frequency range 47 to 63 Hz
Power factor 0.9 to 0.99
Maximum volt-ampere rating 130 VA
BTU/hr 500 MHz processor: 148 (min), 280 (max).