Sun Microsystems Sun Fire V100 Server User Manual


 
70 Sun Fire V100 Server User’s Guide December 2001
To configure the LOM device to perform an automatic server restart (ASR) after a
lockup, you must enable the Hardware reset option as well as the Watchdog
option.
For more information, see “Configuring Automatic Server Restart” on page 73.
To View the Configuration of LOM
To view the settings of all the configurable variables for the LOM device, type:
To View All the Status Data Stored by LOM,
Plus Details of the Device’s Own Configuration
Type:
Code example 6-1 gives sample output of this command.
# lom -c
LOMlite configuration settings:
serial escape character=#
serial event reporting=default
Event reporting level=fatal, warning & information
Serial security=enabled
Disable watchdog on break=disabled
Automatic return to console=disabled
alarm3 mode=watchdog
firmware version=3.0
firmware checksum=2983
product revision=0.0
product ID=Sun Fire 100
#
# lom -a
CODE EXAMPLE 6-1 Sample lom -a output
PSUs:
1 OK
Fans: