Chapter 10 Troubleshooting 107
IDE Controller Failure
The probe-IDE diagnostic transmits an inquiry command to internal and external
IDE devices connected to the system’s on-board IDE interface. If the IDE device is
connected and active, the target address, unit number, device type, and
manufacturer name are displayed. Initialize the probe-IDE diagnostic by typing the
probe-ide command at the ok prompt. The following code example shows the
probe-IDE diagnostic:
Jumper Settings
The default settings for the jumpers are shown below. Do not change these settings.
ok probe-ide
Device 0 ( Primary Master )
ATA Model: ST34342A
Device 1 ( Primary Slave )
ATA Model: ST34342A
ok
Jumper Name Jumper Setting
JP1 1-2
JP3 Not used.
JP7 1-2, 5-6.
JP8 Not used.
JP9 1-2
JP13 Jumper not fitted.
JP14 Jumper not fitted.
JP15 1-2
JP16 Jumper not fitted.
JP18 Jumper not fitted.
JP19 Jumper not fitted.