70
VISION 5000 Videoconferencing SystemAdvanced use
IMPORTANT
The physical interfaces on External
Networks are two non-standard 44 pin
connectors. Special cables are required.
External network settings
==== External Network Settings ====
Call Control:
RS366 Dialling
Leased Line
Data Triggered
Manual
Network Clocking:
RS449/V35 Compatible
X21 Compatible
Advanced Network Settings
Previous Menu
Before using the system together with external network equipment, you must specify the network parameters
on this page.
Note
The system has support for up to 384/512/768 kbps using External Network (RS449/V.35/X.21) interface
depending on software version.
Call control
RS366 Dialling is the only dialling protocol and would normally be used together with network clocking
RS449/V35 Compatible when the external equipment uses RS366 ports.
Leased Line is a non-dialling protocol and should be used when only two codecs are connected in a point
to point connection. Use Leased Line when handshake signals DTR and CD are available. DTR and CD
correspond to the X21 networks C and I signals.
Data Triggered mode uses TxData (transmit data), RxData (receive data) and clock signals only. Use
Data Triggered when no handshake signals are available.
Manual should be used when no handshake signals are available, and the external equipment requires a
constantly connected line.