Ethernet
How is it done
Connect your system to a local area network. The network cable should be connected from the LAN-port at
the rear of the codec to a port in your network using a standard RJ-45 cable.
Configure your codec by performing the following:
Press MENU, select Terminal Settings, TCP/IP Settings
Specify IP-assignment DHCP or Static. If DHCP is selected no other settings are needed. If Static is
selected, IP-address, IP-subnet mask and Gateway must be specified.
Example:
IP-assignment: Static
IP-address: 192.9.200.111
IP-subnet mask: 255.255.255.0
Gateway: 192.9.200.21
See chapter TCP/IP Settings in Advanced use for further information on these settings.
Start your Web-browser. In the address field type the IP-address of the codec
Example: 192.9.200.129
You will now see the front page of the codecs Web-interface.
The following Web-browsers have been tested:
Netscape Communicator 4.05
Microsoft Internet Explorer 4.0 and 3.0
Opera 3.51