Xantrex Technology XDC 20-600 Power Supply User Manual


 
Power Supply Operation
TM-XDOP-01XN 3–47
To set the current limits:
Step # Do This You Will See
1ERROR MSGS
2
until you see the “SETPT LIMIT”
option
SETPT LIMIT
3
Voltage Limit
4 Current Limit
5High 0A
6 Use the Current knob, arrow keys, or
numeric keypad to enter a value. The value
must be within 0A to 103% of the unit’s
rated current and must be higher than the
current setpoint.
High #####A
7Low 0A
The Maximum setting is
saved and the Minimum
setting appears.
8 Use the Voltage knob, arrow keys, or
numeric keypad to enter a value. The value
must be within 0A to 103% of the unit’s
rated current and must be lower than the
current setpoint.
Low #####A
9 The setting is saved and
the display returns to its
default operating mode.
MENU
ENTER
ENTER
ENTER
ENTER