Xantrex Technology XDC 20-600 Power Supply User Manual


 
Error Messages
D–8 TM-XDOP-01XN
CANbus Error Codes
Multichannel Error Codes
Multichannel functionality is only available with the 6000 Watt power supply.
Table D-11
CANbus Error Codes
Error code Error Message Description
+1701 CANbus hardware missing
The CANbus option is not installed on the controller card, or controller card
is not present.
+1702 CANbus device specific error
An error has occurred on the CANbus circuit. Probable causes are AC input
too low, AC input not secure, controller card not securely fastened or other
noise sources.
+1703 CANbus input buffer corrupted.
+1704 CANbus input buffer corrupted.
+1705 CANbus input buffer overrun.
Data is sent on the CANbus faster than the CPU can process.
+1706 CANbus output buffer overrun.
Data cannot be transmitted fast enough.
Table D-12
Multichannel Error Codes
Error code Error Message Description
+1800 Multichannel general error
An error has occurred while sending multichannel commands. One such
cause is sending a command that is too long.
+1802 Multichannel address taken
The multichannel address configured for this unit has already been assigned
to another unit on the CANbus network.
+1803 Multichannel originator not responding
The originator of the message is not responding to the handshaking.
+1804 Multichannel recipient not responding
The recipient of the message is not acknowledging the reception of the
command.
+1805 Multichannel command overwritten
A received command through the CANbus has been overwritten.
TM-XDOP-01XN.book Page 8 Monday, July 17, 2006 11:19 AM