Xantrex Technology XDC 20-600 Power Supply User Manual


 
Remote Operation
4–54 TM-XDOP-01XN
TEMPerature Sub-Register
This shows whether the temperature of critical components is near or over the
maximum operating temperature.
Standard Event Status Register
The standard event status register sets bits for specific events during power supply
operation. All bits in the standard event status registers are set through the error
event queue. The register is defined by 488.2 and is controlled using 488.2
common commands, *ESE, *ESE?, and *ESR?.
Figure 4-6, “IEEE 488.2 Status Register and Status Byte” on page 4–54
summarizes the standard Event Status Register.
Table 4-19
TEMPerature Sub-Register
Bit Bit Weight Bit Name Description
0 1 Over TEMperature Set if the power supply temperature exceeds the maximum
operating temperature.
1 2 High TEMperature Set if the power supply temperature exceeds 90% of the
maximum operating temperature.
Figure 4-6
IEEE 488.2 Status Register and Status Byte
Not Used
Not Used
Not Used
MAV
Standard Event Status Register
1
0
3
2
5
4
7
6
Summary of QUESTionable Status
RQS/MSS
Summary of OPERation Status
1
0
3
2
5
4
7
6
9
8
11
10
13
12
15
14
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
+
Operation Complete
Query Error
Device Dependent Error
User Request
Power On
Execution Error
Command Error
Not Used
TM-XDOP-01XN.book Page 54 Monday, July 17, 2006 11:19 AM