Xantrex Technology XDC 20-600 Power Supply User Manual


 
Power Supply Operation
TM-XDOP-01XN 3–15
Set Shutdown Recovery for AC Off and OTP
The Shutdown Recovery menu offers 2 options for AC Off (ACO) and Over-
Temperature protection (OTP):
Auto-Recovery: With this method, the power supply returns to its normal
operating state once the alarm condition no longer exists. For example, if
there was an over-temperature alarm and the protection was set to auto-
recovery, the power supply would return to its normal operating state once the
temperature was reduced below the alarm level.
Latched: With this method, the power supply remains in Shutdown state until
the operator manually clears the protection level and manually turns the
output back on.
You can set either or both the OTP and AC Off to Auto-Recovery or Latched.
To set both OTP and AC Off to Auto-Recovery:
Step # Do This You Will See
1ERROR MSGS
2
3 times
a
a. You can also press MENU 4 times to bring up the Shutdown Recovery option.
S/D RECOVERY
3
OTP Latched
b
b. The default is Latched. You can leave it at Latched or change it to Auto-Recovery. Press
either arrow key repeatedly until the desired option appears.
4 OTP AutoRecov
5
ACO AutoRecov
c
OTP is set to Auto Recovery.
c. The default is AutoRecov. You can leave it at Auto-Recovery or change it to Latched.
Press either arrow key repeatedly until the desired option appears.
6 ACO remains set to Auto Recovery and the
display returns to its default operating mode.
MENU
ENTER
ENTER
ENTER
TM-XDOP-01XN.book Page 15 Monday, July 17, 2006 11:19 AM