Xantrex Technology XDC 20-600 Power Supply User Manual


 
Remote Analog Operation
TM-XDOP-01XN 4–7
The analog setpoint and readback pins may be configured to work in either a 0–
5V range or 0–10V range.
The programming lines have their own isolated power source (10mA max), and
this power can be looped back to power the user lines, if required. Connect the
pins as shown in Table 4-3.
Remote Interlock Using a Contact Closure
The interlock input may be configured for use with an external voltage free
contact. Connect pins as shown:
Closing an external contact across the interlock pins B2/A4 will then disable the
unit. Opening the contact will enable the supply output.
Table 4-2
Analog Programming Pins
Pin # Function Input/Output
B1 Analog Programming (GND) Output
B2 12V (unregulated) 10mA max Output
B3 Voltage Setpoint (0–5/10V) Input
B4 Current Setpoint (0–5/10V) Input
B5 Voltage Readback (0–5/10V) Output
B6 Current Readback (0–5/10V) Output
Table 4-3
Analog Pin Connections for Power Loop Back
Programming Line Pin # User Line Pin #
B1 to A7
B2 to A6
Table 4-4
Analog Pin Connections with a Contact Closure
Programming Line Pin # User Line Pin #
B1 to A5
TM-XDOP-01XN.book Page 7 Monday, July 17, 2006 11:19 AM