Xantrex Technology XDC 20-600 Power Supply User Manual


 
Specifications and Characteristics
A–2 TM-XDOP-01XN
Electrical Specifications—Summary
Table A-1
Specifications for 6000 Watt units (10V to 60V Models)
Models 10-600 20-300 30-200 40-150 60-100
Output Ratings:
Output Voltage
a
Output Current
b
Output Power
a. Minimum output voltage is <0.3% of rated voltage at zero output setting.
b. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
0–10 V
0–600 A
6000 W
0–20 V
0–300 A
6000 W
0–30 V
0–200 A
6000 W
0–40 V
0–150 A
6000 W
0–60 V
0–100 A
6000 W
Line Regulation:
c
Voltage (0.01% of Vmax)
Current (0.05% of Imax)
c. For input voltage variation over the AC input voltage range, with constant rated load.
1mV
300 mA
2mV
150 mA
3mV
100 mA
4mV
75 mA
6mV
50 mA
Load Regulation:
d
Voltage (0.05% of Vmax + 5 mV)
Current (0.1% of Imax + 20 mA)
d. For 0–100% load variation, with constant nominal line voltage.
10 mV
620 mA
15 mV
320 mA
20 mV
220 mA
25 mV
170 mA
35 mV
120 mA
Meter Accuracy:
Voltage (0.15% of Vmax)
Current (0.5% of Imax)
15 mV
3A
30 mV
1.5 A
45 mV
1.0 A
60 mV
750 mA
90 mV
500 mA
Output Noise (0–20 MHz):
Voltage (p–p) 75 mV 75 mV 75 mV 75 mV 100 mV
Output Ripple (rms):
Voltage
Current
e
e. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
10 mV
3100 mA
10 mV
1600 mA
12 mV
1000 mA
15 mV
750 mA
15 mV
450 mA
OVP Adjustment Range:
(0% to 103% of Vmax) 0–10.3 V 0–20.6 V 0–30.9 V 0–41.2 V 0–61.8 V
Efficiency:
f
f. Typical efficiency at nominal input voltage and full output power.
0.85 0.87 0.87 0.87 0.89
Drift (30 minutes):
g
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
g. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
4mV
3600 mA
8mV
1800 mA
12 mV
1200 mA
16 mV
900 mA
24 mV
600 mA
Drift (8 hours):
h
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
h. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
2mV
240 mA
4mV
120 mA
6mV
80 mA
8mV
60 mA
12 mV
40 mA
Temperature Coefficient:
i
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
i. Change in output per °C change in ambient temperature, with constant line and load.
4mV
360 mA
8mV
180 mA
12 mV
120 mA
16 mV
90 mA
24 mV
60 mA