Xantrex Technology XDC 20-600 Power Supply User Manual


 
Power Supply Operation
TM-XDOP-01XN 3–21
Store User Settings
If you have a frequent or constant need for a specific voltage and current output,
you can save these setpoints in the power supply’s memory as a user setting. Once
a setting is stored, it remains in the power supply’s memory after the unit is
powered off.
Ten user setting memory locations are available, and each saves the following
parameters:
Voltage setpoint
Current setpoint
Power setpoint
Over-voltage protection setpoint (OVP)
Under-voltage protection setpoint and shutdown configuration (UVP)
Over-current protection setpoint and shutdown configuration (OCP)
Under-current protection setpoint and shutdown configuration (UCP)
Over-power protection setpoint and shutdown configuration (OPP)
Under-power protection setpoint and shutdown configuration (UPP)
Foldback protection mode and delay settings
Over-temperature protection auto recovery configuration (OTP)
AC Off auto recovery configuration (ACO)
Aux line configuration
Front panel display configuration
Front panel knob lockout
Voltage, current, and power limits
Triggered voltage, current and power setpoints
Trigger source
Important:
All parameters are saved and used when the user setting is
recalled. Therefore, you should set parameters that you do not care about to the
factory defaults.
TM-XDOP-01XN.book Page 21 Monday, July 17, 2006 11:19 AM