Xantrex Technology XDC 20-600 Power Supply User Manual


 
Specifications and Characteristics
A–10 TM-XDOP-01XN
User Line Interface
Includes auxiliary status lines, interlock, and external trigger lines
Switching Frequency
Typical 31 kHz; 62 kHz output ripple
Rise Time
5 to 95% step in output voltage.
Fall Time
For a programmed 95% to 5% step in output voltage.
Time Delay From Power On Until Output Stable
5 s maximum
(Within regulation envelope)
Time Delay From Output Enable Until Output Stable
2 s maximum
(Within regulation envelope)
Output Hold-Up Time – Power Off
Minimum 4 ms (at full load)
Output Hold-Up Time – Source Interruption
Minimum 4 ms with output deviation less than 5% of maximum output voltage
after source interruption.
Maximum Current Sink
Capability, Each Output 10 mA
Maximum Supply Voltage 15 V
dc
Minimum Supply Voltage 4 V
dc
Isolation 300 Vdc with respect to chassis
potential or negative output
Load Condition Time (Max)
No Load 100 ms
Full Load 100 ms
Load Condition Time (Max)
No Load
a
a. Fall time is 4s for 300 V and 600 V units.
3s
Full Load 50 ms