Specifications and Characteristics
A–6 TM-XDOP-01XN
AC Line Input Specifications
The input to the power supply requires the following specifications.
AC Line Input Voltage Operating Ranges
Operating Range
nominal 208V
rms
(Standard)
nominal 400V
rms
(with HV-Input option)
190 to 242 V
ac
3 φ (3 wire + safety ground)
342 to 500 V
ac
3 φ (3 wire + safety ground)
Frequency Range 47 to 63 Hz
Maximum Peak In-rush Current at turn on
nominal 208V
rms
(Standard)
nominal 400V
rms
(with HV-Input option)
35 A
rms
(6000 Watt)
70 A
rms
(12000 Watt)
19 A
rms
(6000 Watt)
38 A
rms
(12000 Watt)
Minimum Power Factor
a
nominal 208V
rms
(Standard)
nominal 400V
rms
(with HV-Input option)
a. At nominal input voltage and maximum power
0.95
0.9
Operating Current
nominal 208V
rms
(Standard)
Maximum
b
Typical
c
b. At 190V
ac
input voltage, 55°C ambient temperature and maximum power
c. At 208V
ac
input voltage, 25°C ambient temperature and maximum power
24 A (6000 Watt)
48 A (12000 Watt)
20 A (6000 Watt)
40 A (12000 Watt)
Operating Current
nominal 400V
rms
(with HV-Input option)
Maximum
d
Typical
e
d. At 342V
ac
input voltage, 50°C ambient temperature and maximum power
e. At 400V
ac
input voltage, 25°C ambient temperature and maximum power
13 A (6000 Watt)
26 A (12000 Watt)
11 A (6000 Watt)
22 A (12000 Watt)