Xerox 4213 Printer User Manual


 
LJ SERIES 2D EMULATION
Table 3-2. Using parameter and final parameter characters
Upper
case
Lower
case Sequence
XA final parameter in a combination of
escape sequences.
XA single escape sequence.
xA non-final parameter linking a series of
escape sequences.
Binary data
The binary data is optional eight-bit data which is downloaded
immediately after an escape sequence. The length of the binary
data in bytes is normally specified by the preceding numeric
variable.
Figure 3-3. Single Escape Sequence
E
Combining escape sequences
Escape sequences may be written in separate strings (figure 3-3)
or linked together for simplicity (figure 3-4). Commands with
variables may be combined if the variable sequence character and
the group character are the same for each command. The
following rules apply:
The escape character, the variable sequence character, and
the group character are omitted from all but the first escape
sequence when sequences are combined.
3-12 XEROX 4213 LASER PRINTER PROGRAMMER REFERENCE