AMCC 720-0138-00 Computer Accessories User Manual


 
Error and Notification Messages
www.3ware.com 127
003D Verify paused
This message will be sent when the verify operation is paused.
Verifies are normally paused for ten minutes after a system first boots up and
during non-scheduled times when scheduling is enabled.
003E Migration paused
This message is sent when migration is paused. Migration follows the rebuild
schedule. For more information, see “Scheduling Background Tasks” on
page 76.
003F Flash file system error detected
The 3ware RAID controller stores some configuration parameters as files in
its flash memory. This message will be sent when a corrupted flash file system
is found on the controller during boot-up. A further attempt will be made to
repair the flash file system. These files usually get corrupted when a flash
operation is interrupted by events such as power failures.
0040 Flash file system repaired
This message will be sent if a corrupted flash file system is successfully
repaired. Some of the flash files with insufficient data may be lost in the
operation. The configuration parameters which are lost will then return to
their default values.
0041 Unit number assignments lost
The 3ware RAID controller tries to keep the unit numbers persistent across
soft resets. This message will be sent if unit number assignments were lost
from some unknown reasons. (This event rarely happens. Please contact
AMCC 3ware technical support if this event occurs.)
0042 Primary DCB read error occurred
This message will be sent when the controller finds an error while reading the
primary copy of the Disk Configuration Block (DCB). The back-up copy of
the DCB will be read if this error occurs. If a valid DCB is found, the primary
DCB is re-written to rectify the errors found.
If this error occurs, we recommend verifying the unit. See “Starting a Verify
Manually” on page 72.