AMCC 720-0138-00 Computer Accessories User Manual


 
Checking Unit and Drive Status
www.3ware.com 63
Enclosure LED Status Indicators
The LEDs on your enclosure also provide status information about your
drives and units.
Unit Statuses
The following is a list of unit statuses you may see in 3DM:
OK. The unit is optimal and is functioning normally.
Rebuilding. The unit is in the process of writing data to a newly added
disk in a redundant unit, in order to restore the unit to an optimal state.
The unit is not fully fault tolerant until the rebuilding is complete. For
more information, see “Rebuilding Units” on page 73.
Rebuild-Paused. The unit is set to rebuild, however scheduling is
enabled, and the present time is not during a scheduled timeslot.
Rebuilding will start at the next scheduled time slot. Rebuilds are also
paused for up to ten minutes after a reboot, even during a scheduled
timeslot.
Table 8: Meaning of LED Colors and Behavior
Color Drive Status
Solid green OK
Blinking green Identify
This occurs when you have used the Identify command in 3DM
to locate a particular drive or unit. (See “Locating a Drive by
Blinking Its LED” on page 81.)
Black No drive
Solid Amber Hot spare
Blinking amber Rebuilding
The drive in this slot is part of a RAID unit that is currently
rebuilding. You can continue to use the unit. For more
information, see “Rebuilding Units” on page 73.
Solid red Drive fault
This drive has failed. You should replace it and rebuild the unit.
Blinking red Predicted drive fault
3ware software predicts that this drive will fail soon. You may
want to replace it.