6. Under Actions, select Send Notication from the Type drop-down list.
7. Select an email recipient from the drop-down list. See Add Recipients on page 37.
The following example describes how to set up an action rule to activate an output port when the door is forced open.
1. Go to Setup > Additional Controller Conguration > System Options > Ports & Devices > I/O Ports.
2. Select Output from the desired I/O Port Type drop-down list and enter a Name.
3. Select the I/O port’s Normal state and click Save.
4. Go to Events > Action Rules and click Add.
5. Select Door from the Trigger drop-down list.
6. Select Door Alarm from the drop-down list.
7. Select the desired door from the drop-down list.
8. Select DoorForcedOpen from the drop-down list.
9. Optionally, select a Schedule and Additional conditions. See below.
10. Under Actions, select Output Port from the Type drop-down list.
11. Select the desired output port from the Port drop-down list.
12. Set state Active.
13. Select Duration and Go to opposite state after. Then enter the desired duration of the action.
14. Click OK.
To use more than one trigger for the action rule, select Additional conditions and click Add to add additional triggers. When using
additional conditions, all conditions must be met to trigger the action.
To prevent an action from being triggered repeatedly, a Wait at least time can be set. Enter the time in hours, minutes and seconds,
during which the trigger should be ignored before the action rule can be activated again.
For more information, see the online help
.
Triggers
Available action rule triggers and conditions include:
Access Point
- Access Point Enabled – Triggers the action rule when an access point device such as a reader or REX device is
congured, for example when the hardware conguration is completed or an identication type is added.
Conguration
- Access Point Changed – Triggers the action rule when the conguration of an access point device such as a
reader or REX device is changed, for example when hardware is congured or an identication type is edited,
changing the ways through which a door can be accessed.
- Access Point Removed – Triggers the action rule when the hardware conguration of an access point device
such as a reader or REX device is reset.
- Area Changed – Not supported by this version of AXIS Entry Manager. Must be congured by a client such as an
access management system, through the VAPIX® application programming interface, that supports this feature
and use devices that can provide the required signals. Triggers the action rule when an access area is changed.