Confidential
3-51
(8) Disconnect the Connector (CN7), and remove the two bind B M3x8 Taptite screws, and
then remove the Density sensor.
Note:
Do not touch the Variable resistor on the back of the Density sensor.
Fig. 3-37
(9) Disconnect the Flat cable (CN2) and three Connectors (CN6, CN9, CN13) from the
Registration relay PCB ASSY.
Note:
- After disconnecting the flat cable(s), check that each cable is not damaged at its end or
short-circuited.
- When connecting the flat cable(s), do not insert it at an angle. After insertion, check that
the cable is not at an angle.
CN13
CN9
CN2
CN6
Fig. 3-38
Density sensor
Taptite, bind B M3x8
Registration relay PCB ASSY
CN7
Transfer HVPS PCB unit
Connector
Registration relay PCB ASSY
Transfer HVPS PCB unit
Variable resistor