Brother MFC-9840CDW All in One Printer User Manual


 
Confidential
App. 1-20
< WSW15 >
Selector No. Function Setting and Specifications
1
2
Redial interval
No. 1 2
0 0: 5
min.
0 1: 1 min.
1 0: 2 min.
1 1: 3 min.
3
|
6
No. of redialings
No. 3 4 5 6
0 0 0 0: 16
times
0 0 0 1: 1 times
0 0 1 0: 2 times
0 0 1 1: 3 times
|
1 1 1 1: 15 times
7 (Not used.)
8 CRP option 0: Disable 1: Enable
- Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
- Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for
three seconds and then makes a retry three times. This CRP option is a request command
that can be sent from the called station for requesting the calling station to retry the failed
command immediately.